In this article we’ll walk through setting up Auto Receive in DNC-Max, so a program sent back from the machine gets saved automatically, in the right place, without someone at the PC clicking Receive and naming the file by hand. Let’s get started.
What Auto Receive Actually Solves
Without Auto Receive configured, getting a program off a machine means someone manually starting a receive on the PC side, typing a filename, and picking a folder, every single time. That works fine, once in a while, but it does not scale. This is exactly how a shop ends up with a receive folder full of files named NC1, NC2, and FINAL_v3 with no indication of which machine or job any of them actually came from. Auto Receive automates that whole step so a file lands in the correct, predictable location the moment it comes off the control.
Setting the Receive Directory and Extensions
The starting point is the Directories section of the port’s DNC Setup. The “Machine program destination directory” field is where an incoming file gets saved. And it is worth pointing this at a folder specific to that machine rather than a shared catch-all everyone dumps into. A simple structure, one subfolder per machine, removes most of the confusion that shows up later when two machines have both been sending files to the same place.
Deciding What Actually Gets Saved
For serial machines, the Receive settings tab controls what counts as the start and end of a program, which matters more than it sounds like it should. CR/LF can usually stay on Auto, which lets DNC-Max detect the line ending combination the control is using. But sometimes older or nonstandard controls need this set manually.
Two fields are worth checking deliberately rather than leaving on default:
- Start trigger and End trigger mark where the incoming data actually begins and ends. Leave these empty and DNC-Max starts saving immediately and keeps going until a timeout. This is fine for many controls, but can pick up stray characters or a partial transmission on others. If your shop has ever received a program that would not open correctly, this is one of the first places to look.
- Receive timeout in seconds determines how long DNC-Max waits after the last character arrives before deciding the transfer is done. Too short and a slow control gets cut off mid-file. Too long and a stalled connection sits open longer than it needs to. There is no single right number here. It depends on the control. So it’s worth testing with a real program rather than trusting the default.
The Omit lines, containing Omit Strings and Omit empty lines options, let you strip out anything the control sends which has no business being in the saved file, like blank lines or characters your post-processor never expected to see. Configured well, this means the file that lands in the folder is one a programmer can open and trust right away, not one that needs a cleanup first.
A Quick Note on Advanced Receive Settings
If a control needs software handshaking to receive cleanly, Send XOn tells DNC-Max to send that signal once it is ready to receive data. Send at start of reception lets you specify a string sent to the control the moment a receive begins. Most shops will never touch these. But they are worth knowing about if a receive is technically completing but the control seems to be waiting on something the PC never sent.
Testing Before You Trust It
Once configured, do not assume it’s right just because the screen closed without an error. Send a program back from the actual machine and confirm it lands in the folder you expect, under the extension you expect, and that it opens cleanly. A setup that looks correct on the configuration screen still needs a real test before you build a daily habit around it.
Getting the file back is one step. Deciding whether its changes should become the approved version is another. If your shop uses CIMCO NC-Base or CIMCO MDM alongside DNC-Max, an Import Queue can hold incoming programs for review before they replace the approved database version. Our article on understanding the Import Queue in CIMCO NC-Base and CIMCO MDM explains how that review process works.
In Conclusion
Configured with a bit of intention, Auto Receive stops being a black box that either works or does not. It becomes the quiet, reliable reason a program comes back from the machine exactly where it belongs.
Have Questions or Need Help?
Every shop is different. If you have questions about CIMCO software or need help solving a specific programming, communication, or manufacturing workflow challenge, Managed Solutions is here to help.
Visit our CIMCO DNC-Max product page to learn more about managing CNC program transfers. If you need help configuring Auto Receive, organizing receive folders, or troubleshooting transfers from your machine controls, contact our team. We’ll be happy to walk through it with you.