Drip feeding often gets treated as a mysterious setting that shops either always use or never touch, when really it solves one specific problem.
In this post, we’ll explain how drip feeding works in CIMCO DNC-Max, which programs and controls actually require it, and how to avoid turning it on for a machine that does not need it. Let’s get started.
What Drip Feeding Actually Does
A CNC control has a limited amount of internal memory for storing a program. Most modern controls can store an entire program in memory before running it, which means the whole file gets transferred over, sits in memory, and then executes.
Drip feeding is a different mode entirely. Instead of transferring the whole program up front, the DNC connection sends the program to the control in a steady stream, one block at a time, in sync with the control actually executing each block as it runs.
In other words, with drip feeding, the program is never fully stored on the control. It is being fed in continuously while it runs, which means if the connection drops mid-program, the machine stops because it has run out of code to execute next, not because of a crash or a fault.
When You Actually Need It
Drip feeding exists for one real reason, the program is too large for the control’s available memory. This typically comes up with:
- Long, continuous toolpaths from complex 3D surfacing operations, especially on 5-axis work, where the program can run into hundreds of thousands of lines.
- Older controls with genuinely limited memory capacity compared to what a modern CAM package can generate.
- High-density point clouds from surface finishing operations where the block count is far higher than a typical prismatic part.
If a program will not fit in the control’s memory as a complete file, drip feeding is not optional. It is the only way to run that program at all.
When You Do Not Need It
For the overwhelming majority of everyday programs – standard milling and turning work, most prismatic parts, and reasonably sized subroutines – the program will load into the control’s memory just fine as a complete file.
In these cases, drip feeding adds a live dependency on the DNC connection that does not need to exist. If the connection blips for even a moment during a program that did not need drip feeding in the first place, you have introduced a new failure point for no benefit.
The practical test is simple. If the program loads and runs fine as a complete transfer, leave drip feeding off for that program. Only turn it on when you know the file size is actually exceeding what the control can hold.
Configuring Drip Feed Settings Correctly
When you do need drip feeding, the relevant settings live in the machine’s Transmit Settings. Getting them right is what separates a smooth continuous feed from a machine that stutters or faults mid-cycle:
-
- Delay before each line (ms): How long to wait before transmitting each new line. Too short a delay on a slow connection can outrun what the control can accept.

- Handshake timeout (seconds): How long to wait after receiving a stop-flow signal from the control before giving up on the connection. Set this too short and a normal, brief pause from the control can be mistaken for a dropped connection.

- Delay before each line (ms): How long to wait before transmitting each new line. Too short a delay on a slow connection can outrun what the control can accept.
- Wait for XOn: When enabled, the DNC waits for an XOn signal before transmitting, which requires software handshake to be enabled in the port settings. This is often the setting that actually keeps a drip feed connection synchronized with what the control can accept in real time.

- Start trigger and End trigger: Define exactly where in the file transmission should begin and end. Useful when a program has header information you do not want sent as part of the executing feed.


Whenever you set up drip feeding on a new control for the first time, run a full test part with the machine at a safe, reduced feed rate before trusting it at full production speed. A drip feed configuration which is even slightly off tends to show up as a stall exactly where the timing is tightest, which is not somewhere you want to discover it for the first time on a real job.
Use Drip Feeding When Your Program Needs It
Drip feeding solves a specific memory limitation. It comes with a real dependency on connection stability while the program runs. Reserve it for the programs that genuinely exceed the control’s memory, and leave it off everywhere else. Let us know in the comments if you have run into a control that needed drip feeding you were not expecting.
Have Questions or Need Help?
Every shop is different. If you have questions about CIMCO software or need help solving a specific programming, communication, or manufacturing workflow challenge, Managed Solutions is here to help.
Visit our CIMCO DNC-Max product page to learn more about CNC communications. If you need help determining whether your programs require drip feeding or configuring transmit and handshake settings for your specific machines and controls, contact our team. We’ll be happy to walk through it with you.
+1 (925) 736-9114
managedsolutions.com









